From high-efficiency district chiller plants and VRV/VRF systems to cleanroom air filtration, industrial ventilation, and in-house cooling tower manufacturing—monitored live via interactive 3D digital twins.
Authorized Engineering & OEM Technology Integrations
Supervise multi-megawatt central chillers, multi-zone VRV/VRF networks, and enterprise BMS telemetry in real-time. Switch tabs below to inspect live 3D models, animated outdoor units, and multi-floor indoor cassette states.
Flooded Shell & Tube • Magnetic Bearing Oil-Free Technology
Model: Sofia High-Amb 28 HP DC Inverter Scroll • R410A
| Register | Point Name | Protocol | Live Value | Status |
|---|---|---|---|---|
| 40001 | ODU_INVERTER_FREQ_HZ | Modbus RTU (485) | 68.5 Hz | VALID |
| 40002 | ODU_ACTIVE_POWER_KW | Modbus RTU (485) | 18.4 kW | VALID |
| 40015 | IDU05_FILTER_DP_SW | BACnet / IP | 0.85 bar (DIRTY) | WARNING |
| 40018 | IDU06_DRAIN_PAN_FLOAT | BACnet / IP | TRIPPED (HIGH) | ALARM A3 |
| 30045 | CH01_CHILLED_LWT | BACnet / IP | 7.1 °C | SETPOINT MATCH |
| 30046 | CH01_COND_EWT | BACnet / IP | 31.2 °C | NOMINAL |
| 10008 | TOWER01_VFD_SPEED_PCT | BACnet MSTP | 85.0 % | MODULATING |
[07:50:12] Polling BACnet/IP Gateway #01... OK
[07:50:14] ODU Inverter PID locked at 68.5 Hz
[07:50:16] Modbus slave 14 (IDU-01) setpoint 22.0°C
[07:50:18] ALARM: IDU-05 Filter Differential Pressure high
[07:50:20] LOCKOUT: IDU-06 Float switch open (A3 Alarm)
[07:50:22] Chiller 01 Flooded Evaporator LWT steady at 7.1°C
[07:50:24] Cooling Tower VFD modulated to 85% RPM
[07:50:26] Continuous telemetry loop active
Click any node in our refrigeration cycle to inspect live fluid dynamics, heat exchange principles, and equipment specifications.
Compresses low-pressure refrigerant vapor from the evaporator, boosting its temperature and pressure using variable frequency magnetic bearing technology for ultra-high seasonal efficiency (IPLV > 9.5).
Unlike conventional MEP contractors who rely on third-party tower fabricators, Sofia Cooltech manufactures its own heavy-duty FRP Induced Draft Counterflow and Crossflow Cooling Towers.
Built with UV-stabilized hand-laid fiberglass resin and virgin PVC honeycomb film fills, our towers deliver 100% rated thermal duty even when ambient temperatures in North India exceed 45°C.
Impervious to harsh groundwater, chemical dosing, and industrial airborne acidity.
Multi-pass cellular drift eliminators restrict water loss to less than 0.005%.
Calculate estimated tonnage (TR), supply air delivery (CFM), and annual electricity bill savings based on your specific building layout.
From engineering planning and heat-load design to equipment supply, installation, testing, balancing (TAB), and long-term AMC.
Turnkey engineering of water-cooled centrifugal, screw, and air-cooled scroll chillers. Magnetic bearing oil-free chillers for maximum energy reduction.
Certified system design with Daikin, Voltas, and Blue Star. Multi-zone climate control for hotels, high-end offices, and villas with minimum duct ceiling loss.
Commercial kitchen exhaust hoods with electrostatic precipitators (ESP), basement smoke evacuation with impulse jet-fans, and process wet scrubbers.
Strict ISO 14644 & NABH compliant sterile air systems. Laminar flow ceilings for Operation Theaters, positive pressure containment, and terminal HEPA filtration.
Complete HT/LT substations, transformer erection, custom Motor Control Center (MCC) panels, synchronized DG sets, and PLC/SCADA automation.
Complete NBC and NFPA certified life-safety systems. Wet riser hydrants, automated sprinkler networks, diesel fire pump rooms, and addressable smoke detection.
Director, Sofia Cooltech Engineers
Under the direct guidance of Director Abhishek Khan, Sofia Cooltech Engineers has transformed into a premier MEP engineering firm trusted by hospitals, five-star resorts, and heavy industrial facilities across India and abroad.
Abhishek Khan’s core principle is simple: HVAC and MEP designs must anticipate site realities. From extreme summer ambient spikes (45°C+ in Rajasthan) to hard groundwater scaling in cooling towers, his hands-on site coordination ensures every chiller, duct run, and electrical panel operates with peak longevity.
Ducts, chilled water pipes, cable trays, and fire sprinklers are modeled in 3D prior to fabrication—eliminating on-site rework.
Dedicated team of 50+ technicians in Jaipur ready for emergency breakdown response, seasonal descaling, and air balancing.
Read verified feedback from factory owners, hospital administrators, and commercial developers who rely on Sofia Cooltech.
"We are extremely satisfied with the cooling tower installation and thermal water circuit done by Sofia Cooltech Engineers at our clothing manufacturing unit. The system has performed flawlessly through two scorching summers."
"The team was responsive, technically knowledgeable, and thoroughly cooperative throughout our HVAC and fire-fighting contract. Their adherence to NBC standards made our municipal clearance effortless."
"Cooling tower installation and heavy ventilation work at our plastic bottle manufacturing plant in Prahladpura was delivered on schedule. Excellent after-sales and preventive maintenance support."
Share your facility type, tentative square footage, or existing architectural drawings. Our technical estimation desk reviews and responds within one business day.
68, Jayanti Vihar, Sarna Dungari, Jhotwara, Jaipur 302012, Rajasthan, India
+91-8854865628 (Fastest response)
Chat directly with Director Abhishek Khan and our project engineers.
Enter your requirements below and our estimation team will draft an equipment schedule.